Old numbering in square brackets
  
 
[1]- "GFI Lights" and smoke detectors
 
[1]- "GFI Lights" and smoke detectors
  
[2] - powder room, dining rm overhead (no outlets), kitchen lights+fan, mud room lights  
+
9 [2] - powder room, dining rm overhead (no outlets), kitchen lights+fan, mud room lights  
  
 
[3] - Garage ceiling, front foyer light, veranda lights
 
[3] - Garage ceiling, front foyer light, veranda lights
 
* Also leftmost switch by side of front door but load unidentified
 
* Also leftmost switch by side of front door but load unidentified
  
[4] - furnace rm lights, basement stairs, FR1, LR1,2, Hall 1, Entry 1
+
24 [4] - furnace rm lights, basement stairs, FR1, LR1,2, Hall 1, Entry 1
  
[5] - rear bathrm, exercise rm, hall light
+
17 [5] - rear bathrm, exercise rm, hall light
 
* LR3,5,6,7
 
* LR3,5,6,7
 
* ER1
 
* ER1
  
[6] - kitchen, basement outlet near water heater
+
13 [6] - kitchen, basement outlet near water heater
  
[7] - outlet opposite foot of basement stairs (OCS), dining rm, kitchen
+
23 [7] - outlet opposite foot of basement stairs (OCS), dining rm, kitchen
  
 
[8+9] Subpanel
 
[8+9] Subpanel
Line 31: Line 33:
 
16 Blank
 
16 Blank
  
[17] - Den + back of upper BR2 (rear of hall side + hall side of rear) + 2 rear upper hall lights
+
16 [17] - Den + back of upper BR2 (rear of hall side + hall side of rear) + 2 rear upper hall lights
  
[18] mud room door+basement storage rm (?), main floor hall light (adj. family room)
+
18 [18] mud room door+basement storage rm (?), main floor hall light (adj. family room)--but as of 2020-08-25, *not* the mud room
  
[19] - main floor bedroom, entertainment ctr outlet
+
14 [19] - main floor bedroom, entertainment ctr outlet
 
* LBR1,2,3
 
* LBR1,2,3
 
* LBR Closet fixture
 
* LBR Closet fixture
Line 43: Line 45:
 
[20] - ? - OFF
 
[20] - ? - OFF
  
[21] master br + uppr BR2 + 1st light upstairs hall + Upstairs hall outlets 2 & 3
+
20 [21] master br + uppr BR2 + 1st light upstairs hall + Upstairs hall outlets 2 & 3
 
* Two other three-way switches at top and bottom of stairs (other than hall light 1) are on one of circuits 12-13-20-23.  Load unidentified, possibly whole-house fan.
 
* Two other three-way switches at top and bottom of stairs (other than hall light 1) are on one of circuits 12-13-20-23.  Load unidentified, possibly whole-house fan.
  
 
[22] - kitchen fridge?
 
[22] - kitchen fridge?
  
[23] - Outlet to left of water heater - "Xmas lights"
+
13 [23] - Outlet to left of water heater - "Xmas lights"
  
[24] - furnace
+
11 [24] HVAC Blower
  
 
[25+26] 240V upstairs (den?)
 
[25+26] 240V upstairs (den?)

Revision as of 15:31, 25 August 2020

Old numbering in square brackets

[1]- "GFI Lights" and smoke detectors

9 [2] - powder room, dining rm overhead (no outlets), kitchen lights+fan, mud room lights

[3] - Garage ceiling, front foyer light, veranda lights

  • Also leftmost switch by side of front door but load unidentified

24 [4] - furnace rm lights, basement stairs, FR1, LR1,2, Hall 1, Entry 1

17 [5] - rear bathrm, exercise rm, hall light

  • LR3,5,6,7
  • ER1

13 [6] - kitchen, basement outlet near water heater

23 [7] - outlet opposite foot of basement stairs (OCS), dining rm, kitchen

[8+9] Subpanel

10 Blank

11 Blank

[12+13] Deck (formerly) - OFF

14 Blank

15 Blank

16 Blank

16 [17] - Den + back of upper BR2 (rear of hall side + hall side of rear) + 2 rear upper hall lights

18 [18] mud room door+basement storage rm (?), main floor hall light (adj. family room)--but as of 2020-08-25, *not* the mud room

14 [19] - main floor bedroom, entertainment ctr outlet

  • LBR1,2,3
  • LBR Closet fixture
  • LR4
  • ER2,3,4,5

[20] - ? - OFF

20 [21] master br + uppr BR2 + 1st light upstairs hall + Upstairs hall outlets 2 & 3

  • Two other three-way switches at top and bottom of stairs (other than hall light 1) are on one of circuits 12-13-20-23. Load unidentified, possibly whole-house fan.

[22] - kitchen fridge?

13 [23] - Outlet to left of water heater - "Xmas lights"

11 [24] HVAC Blower

[25+26] 240V upstairs (den?)

[27+28] AC

[29] "Outside lighting" - OFF

[30+31] "Generator"

20180623 LettermanMainPanel.jpg
20180623 LettermanSubPanel.jpg
  • Rear bathroom wall fixture wiring
    • Plain Molex--switch
    • Taped Molex--GFCI outlet
    • Sheathed--Power